SYNC-SWITCH - MANUAL 17
-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
SYNC-SWITCH – Manual – Rev 1.1 - 17 -
In order to check that the Transparent Clock feature is properly working is possible to analyze the Ethernet traffic and
verify that the correction field of the PTP Event messages is being correctly updated.
When Synchronous Ethernet and transparent clock feature are both enabled the PPS reconstruction from PTP slaves
achieves a great performance boost due to the reduced Packet Delay Variation.